淮南分析仪厂家直销
Procedure-SolidSamplesInstrumentcalibration/driftcorrection.Placethecalibration/driftstandardina***NickelBasket,andifapplicable,placethesampleintotheappropriateautoloaderposition.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.Note:samplesusingautomationshouldbeplacedintheappropriateautoloaderpositionbeforestartingtheanalysissequence.Oncethesequencehasstarted,theautomaticanalysiswillstartandendautomatically.上海禹重实业有限公司致力于提供分析仪,有需求可以来电咨询!淮南分析仪厂家直销
SoftwareFeatures&BenefitsCornerstonebrandsoftwareisdividedintofourmainsections—Analysis,Diagnostics,Settings,andInstrument—forsimplifiednavigationandorganization.Toolbars,sliders,anddrop-downmenusmakeiteasytosetparametersforcalibrationanddataprocessing.Thesoftwarealsoincludesreal-timeambientmonitors,withfullyanimatedsystemdiagrams.Advanceddiagnosticfeaturesincludeathoroughdigitalon-boardmanual,maintenanceanimations,photoillustrations,黄山力可氧氮氢分析仪厂家供应上海禹重实业有限公司致力于提供分析仪,有想法可以来我司咨询。
SamplePreparationSamplingandsamplepreparationisanimportantissuebecausetraditionalmethodsusedtoobtainsamplesforoxygenandnitrogendeterminationaredifferentfromthoserecommendedforhydrogen,especiallywhensamplingmoltenmetal.Themaindifferenceinsteelsamplingproceduresforoxygen/nitrogenandhydrogenisduetothemobilityofhydrogen.Specialprecautionsmustbeusedwhensamplingforhydrogen.Frommoltensteelandiron,asamplemustbequicklyquenchedincoldwaterandchilledinarefrigerantsuchasliquefiednitrogenoramixtureofacetoneandsolidcarbondioxideinordertoreducelossesofhydrogenfromdiffusion.Lossesofoxygenandnitrogenfromdiffusionarenotaproblem.Asamplethatistakenforhydrogenandchilledinarefrigerantcanalsobeusedforoxygenandnitrogendetermination.However,asamplethatistypicallytakenforoxygenand/ornitrogendeterminationisnotsuitableforhydrogendeterminationduetohydrogenloss(diffusion).Surfacecontaminationmustberemovedbyfilingorlightgrinding,usingcarenottooverheatthesample.
氧氮氢分析仪的常见故障及解决方法仪器启动时显示。没有水流。系统分析电流切断,分析停止。这是水流探测器不正常,水泵不工作,管道堵塞。将仪器的右面板取下,观察水流探测器,用手挤压补水塑料水瓶,发现水流正常,显示正常,证明水流探测器正常,管道畅通。启动循环水泵,但分析仪显示没有水流,此时可判定水泵不正常。打开水泵转子密封口,启动泵发现电机正常运转,此时关闭进水,拆下水泵,发现叶轮脱落。经了解,判定是由于外部冷却水停水,仪器内循环水温过高(水温应≤70℃),致使叶轮(叶轮材料PVC)热胀并脱轴。用粘合剂粘合叶轮后再粘于叶轮轴上,待粘合剂凝固后试车,仪器运行正常。上海禹重实业有限公司致力于提供分析仪,有想法的可以来电咨询!
SamplePreparationTypically,titaniumandzirconiumsamplesarechemicallyetchedtoremovesurfacecontaminationwhenoxygenandnitrogenaredetermined.However,etchingcanintroducehydrogenintothesample.ASTMmethodE1409"DeterminationofOxygenandNitrogeninTitaniumandTitaniumAlloysbytheInertGasFusionTechnique",asupdatedin1996,permitseitheretchingorabrading(filing)ofthetestspecimen.ASTME1447"DeterminationofHydrogeninTitaniumandTitaniumAlloysbytheInertGasFusionThermalConductivity/InfraredDetectionMethod"permitssurfacepreparationbyabrading(ifnecessarytoremovecontamination).DifferencesinsamplepreparationpresentsomewhatofadilemmaregardingsimultaneousdeterminationofO,N,andHintitanium.However,abradingsampleswithafiletoremovesurfacecontaminationwillyieldaccurateO,N,andHresults.TheONH836utilizesahigh-powerelectrodefurnacetoquicklyandefficientlyreleasethetargetgasesfromwithinthesample,whichallowsforaveryrapidsimultaneousdeterminationofoxygen,nitrogen,andhydrogen.分析仪,就选上海禹重实业有限公司。芜湖原装分析仪价格
上海禹重实业有限公司致力于提供分析仪,欢迎您的来电哦!淮南分析仪厂家直销
氧氮氢分析仪的常见故障及解决方法:氧和氮空白值超过20。这是由于气流小,不能将炉子中的空气驱赶出去。可调节气体流量,调节载气压力在0.2~0.4MPa。接通仪器载气,放一个石墨坩埚在下电极上,打开主电源开关,点击软件上的关炉按钮,关闭炉子并等待10s。调节流量调节器,直到流量计a显示为30L/h,打开炉子。调节调节器直到流量计b显示为50L/h,再次关闭炉子。如果以上设置不稳定,则增加流量至100L/h,反复调节直至仪器稳定。淮南分析仪厂家直销
上海禹重实业有限公司主营品牌有赛默飞世尔,发展规模团队不断壮大,该公司服务型的公司。公司是一家有限责任公司(自然)企业,以诚信务实的创业精神、专业的管理团队、踏实的职工队伍,努力为广大用户提供***的产品。公司业务涵盖光谱仪,色谱仪,质谱仪,样品前处理,价格合理,品质有保证,深受广大客户的欢迎。禹重科技自成立以来,一直坚持走正规化、专业化路线,得到了广大客户及社会各界的普遍认可与大力支持。
上一篇: 镇江进口赛默飞近红外分析仪多少钱