Oxygen,Nitrogen,andHydrogeninRefractoryMetalsSummaryTitaniumisametalthatcanbecombinedwithelementssuchasaluminum,vanadium,molybdenum,andtintoproducehigh-strength,lowdensity,andcorrosion-resistantalloys.Titaniumalloysareusedbythemilitary,medicaldevices,sportinggoods,andaerospaceindustriesbecauseoftheseproperties,andduetothestrictdemandsoftheseindustries,effortneedstobetakentoassurethatthematerialmeetsthehighestofqualitystandards.上海禹重实业有限公司为您提供分析仪。盐城力可氧氮氢分析仪厂家直销
Instrumentcalibration/driftcorrectionf.Cleantheupperandlowerelectrodemanually,or,ifapplicable,removethecrucibleandpresstheanalyzebuttontocleanwiththeautomaticcleaner.g.Firmlyplaceagraphitecrucibleonthelowerelectrodetip.h.PresstheAnalyzebuttonontheinstrumentscreen,thelowerelectrodewillcloseandtheanalysissequencewillstartandendautomatically.i.Repeatsteps3bthrough3haminimumofthreetimesforeachcalibration/driftstandardused..Calibrate/driftfollowingtheprocedureoutlinedintheoperatorsinstructionmanual.滁州LECO氧氮氢分析仪厂家直销上海禹重实业有限公司是一家专业提供分析仪的公司,欢迎您的来电!
氧氮氢分析仪的使用注意事项:1、氧氮氢分析仪在初次启用前,应该对连接点、焊点、阀门等进行检漏,以确保空气中的氧不会反渗进入管道及仪器内部,造成测量数值偏高。2、再次使用仪器前,要进行管道系统净化,将漏入的空气除干净,同时确保连接取样管路时没有漏入空气。3、样气中氧含量的变化会受管道材质及表面粗糙度影响,因此一般连接管路选用铜管或抛光过的不锈钢管,而不用塑料管、橡胶管等。4、微量元素分析时,要避免各种管件、阀门、表头等死角对样气造成污染,因此必须尽可能的简化气路系统,连接件死角要小,以防止溶解氧逸出造成污染,使用水封、油封及腊封等设备,才能较好的确保数据的。
氧氮氢分析仪的常见故障及解决方法:氧和氮空白值超过20。这是由于气流小,不能将炉子中的空气驱赶出去。可调节气体流量,调节载气压力在0.2~0.4MPa。接通仪器载气,放一个石墨坩埚在下电极上,打开主电源开关,点击软件上的关炉按钮,关闭炉子并等待10s。调节流量调节器,直到流量计a显示为30L/h,打开炉子。调节调节器直到流量计b显示为50L/h,再次关闭炉子。如果以上设置不稳定,则增加流量至100L/h,反复调节直至仪器稳定。上海禹重实业有限公司是一家专业提供分析仪的公司,有想法的不要错过哦!
Procedure–Powder/ChipSamplesPreparetheinstrumentasoutlinedintheoperatorsinstructionmanual.Determinetheinstrumentblank.LoginaminimumofthreeBlankreps.PresstheAnalyzebuttonontheinstrumentscreen.Afterashortdelay,theloadingheadslide-blockwillopen.Inserta***NickelCapsule(leavecapsuleopen)intotheopenportattopofloadinghead.Note:samplesusingautomationshouldbeplacedintheappropriateautoloaderpositionbeforestartingtheanalysissequence.Oncethesequencehasstarted,theautomaticanalysiswillstartandendautomatically.分析仪,就选上海禹重实业有限公司,用户的信赖之选。宁波原装分析仪厂家供应
上海禹重实业有限公司是一家专业提供分析仪的公司,有想法的可以来电咨询!盐城力可氧氮氢分析仪厂家直销
氧氮氢分析仪的常见故障及解决方法供电正常、通讯正常,点击确认键后分析仪不工作。这是没有水流,炉子温度太高或仪器通道电压不正常。如没有水流,炉子温度太高这些信息会显示在显示器画面上,但没有信息显示说明这两项正常。接下来检查仪器通道零位电压,如果比±3V高出1V以上,可能是因为气瓶空了,或者是空气进入到分析仪中。检查并更换化学试剂,如果有空气进入热导池里,热导池的电压就会<-6V,此时打开右面的门,堵住炉子气体进口,10s后,热导池电压值必然升高。经过逐一排查,**终确认碱石棉有问题,更换后仪器正常。盐城力可氧氮氢分析仪厂家直销